Wearable Exo-musculature Soft Robots

company logo for WPI AIM WPI AIM

Country: United States of America

Summary

A wearable rehabilitation device that would allow patients suffering from hemiparesis to perform repetitive motion therapy in their homes.

Status: Prototype, Research

Operation: Wearable

Robot Type / Domain: Research, Medical & Healthcare

Tasks: restoring lost motor skills

Learn More

Below is from: http://aimlab.wpi.edu/research/projects/Wearable_Exo-musculature_Soft_Robots

"The project has built upon our initial work focused on the development of a cable actuated glove for stroke rehabilitation that was followed up with work on developing a cable actuated elbow and wrist. The goal of our work in soft robotics is to develop a wearable rehabilitation device that would allow patients suffering from hemiparesis to perform repetitive motion therapy in their homes. This therapy is commonly used in restoring lost motor skills by helping the brain rebuild neural pathways lost as a result of disease or trauma such as stroke. In removing the need for a physical therapist to conduct these exercises, the patients would be able to devote more time to their therapy at a lower cost while achieving a greater level of independence.

Our soft robotics work by actuating the user's joints with pairs of antagonistic cables (as one shortens the other extends) with one cable of each pair responsible for flexion and the other for extension. These cables are routed with the use of a Bowden cable system and are actuated by DC motors, each with a spool specially sized to reel in, and let out, the needed amount of cable for that joint. 3D printed cable guides are attached to the fingers and arm to turn cable tension into joint torque. The goal is to eventually package all components into a backpack allowing the system to be mobile either by carrying it on the person or on the back of a wheelchair.

The highly geared DC motors we employ for actuation allow for the development of an inexpensive system with high torque and power densities and allow for the potential of a portable system. Some of the drawbacks include the inherent non-compliance of the actuators. To increase safety, comfort, and effectiveness of the design we are exploring means of adding compliance and developing active stiffness control. For elbow actuation, we are employing series elastic actuators to introduce mechanical compliance and allow for accurate sensing of joint torque. For finger actuation we are looking into using a damper with variable damping coefficient placed in series with the motor. This method has the potential for higher bandwidth and higher fidelity force tracking over series elastic actuators as well as being better suited to adapting to various load impedances. With this control we will look to develop effective exercise routines which can safely and naturally actuate the user's joints.

To add feedback for the control of the orthotic we will be incorporating flex sensors, pressure sensors, and EMG surface electrodes. We plan to use EMG signals to determine grasp and elbow flexion intent allowing for user input to the control. In collaboration with Prof. Ted Clancy's group at WPI we are working to incorporate the surface mount electrodes featured in the robotic rehabilitation devices into a standalone system that could be worn by any user and be able to accurately read their electromyograpic signals. The project is being focused around standardizing the electrodes used for sEMG work from previous rehab projects and adapting them such that they can be mounted in a soft compliant housing that the user can put on and be used without any major set up or accommodations being needed to use."

Technical Specifications

Max. Size: N/A

Max. Payload: N/A

Weight: 6 kg

Weight: 13.228 lbs

DOFs (total): N/A

Battery Operated? N/A

Average Runtime: N/A

Max. Runtime: N/A

Battery Recharge Time: N/A

Body Part: Specific segment, Specific joint, Other, Arm

Purpose: Recovery / Rehabilitation

Mobility: Mobile

Structure: Soft

Action: Active / Powered

Powered Tech: Electric Actuator, Mechanical System, Other, None

IP Rating: N/A

Operating Temperature: N/A

Open-source? N/A

Price: N/A

Force: It can supply a 15N tensile force for this actuation and for grip strength

Material: The material of the glove is a spandex, moisture-wicked material (Seirus Innovations, Thermax Deluxe Glove Liner). 3D printed cable guides.

Actuators: The servomotors used (HiTec 5465 series) were able to rotate from 0◦ to 200◦

No more specs to show.

Please visit the official website for more accurate, up-to-date, and complete information on this post. Visit Website   External Link Icon

References

  • Brauckmann M, Calamari E, Lipkind S, Leone B, Molica C, Piscopiello A, Terry W, Delph MA, Torres-Jara E, Popovic MB, Clancy EA, Fischer GS, Soft Exo-Skeletal Arm for C4-C5 Trauma Induced Spinal Cord Injuries, Biomedical Engineering Society Annual Meeting - BMES, Seattle, WA, September 2013. 
  • Delph II MA, Fischer SA, Gauthier PW, Martinez Luna CH, Clancy EA, Fischer GS, A Soft Robotic Exomusculature Glove with Integrated sEMG Sensing for Hand Rehabilitation, 13th International Conference on Rehabilitation Robotics (ICORR), Seattle, WA, June 2013.

Disclaimer: For informational purposes only. The provided data and/or content are intended as references and may contain errors. We appreciate your help in maintaining accuracy; if you spot any errors, please notify us. For the most reliable and up-to-date information, kindly refer to the official website. By using addoobot and its contents and services, you agree to our Terms and Conditions, Privacy Policy, and Cookie Policy.